Skip to content

AirMesh 1031 (0017)

4.0.2 - 2024-06-25

  • MT protocol version 1.10

Fixed

  • The MT message was not dequeued if it failed to send due to an error.

4.0.0 - 2023-12-14

  • MT protocol version: 1.9

Added

  • Establishing connections faster
  • New broadcast/multicast feature
  • Firmware broadcast support

Changed

  • Firmware download improvements
  • Upstream queue improvements

Fixed

  • Fixed bug that could cause the device to brick under certain conditions when aborting firmware upgrade.

Removed

  • Property support
  • 0x8123 - Start Firmware Update with Model Number
  • 0x9001 - Antenna Type
  • 0x8006 - Production Info
  • 0x8020 - Power Source

3.0.0 - 2022-11-01

  • MT protocol version: 1.5

Added

  • Firmware update timeout will only apply during download. If the firmware image is downloaded within given timeout, the timeout will set to zero and the device will wait for a new image to apply.
  • Added property:
  • 0x8160 - Ping Counter

Changed

  • Removed 0x8101 - Uptime reporting. It is now read-only.

Fixed

  • Reading property 91.00 - Uplink RSSI value returned 0

2.1.0 - 2021-12-15

  • MT protocol version: 1.1

Added

  • Added event:
  • 0x8113 - Watchdog Reset

Changed

  • Used software reset instead of watchdog reset for radio off event in storage and also network data (device status) successful notification in connected mode.

2.0.0 - 2021-04-27

  • MT Protocol Version: 1.1

Added

  • 3 more priority level i.e. system, system high, critical
  • Logic to resend critical priority message on reconnect (with same route) if it seems lost due to disconnection.
  • Handled critical priority message lost scenario - disconnected the uplink - and flushed uplink queues.

Changed

  • Improved uplink queue for better traffic utilization

Fixed

  • Fixed heartbeat periodic reporting issue. It was reported only once on joining the network.
  • Fixed traffic priority in uplink

[1.1.1] - 2021-02-06

Fixed

  • Property 0x9010 - Default Pins State were not applicable

1.1.0 - 2021-02-02

Added

  • Report internal error (0x0030) on write request in case of writable and null property.
  • Support of property not applicable (0x0026) status code
  • 10ms delay in connect heartbeat to delay it from application packet.
  • Logic to re-request firmware block early (in some cases) instead of waiting for 30 second.

Changed

  • Allow multiple bits in key.
  • In multiple bit compare result of key, consider highest AND-result value. Also the RSSI is above the threshold value.
  • Allow to set Scan window between 15% - 95%. It was 5% - 95% before. If value < 15 already stored in flash, Set to 15%.
  • Minimum possible value for heartbeat interval is 60 seconds instead of 1 second.
  • Set 60ms delay between two dfu packet.
  • Do not reset device on firmware update timeout.

Fixed

  • Device stop scanning between 5% - 11% scanning window setting.
  • Fixed device type reporting
  • Firmware update fixes

1.0.0 - 2020-10-30

Initial release.